Clear-Com Communication Systems Page 67 of 100
Tempest 2400 Wireless Intercom System
Charging the Lithium-Polymer Battery
With the Lithium-Polymer batteries installed in the battery compartment, plug the
AC end of the supplied 5VDC Charger/Power Supply into a standard AC wall
outlet. Open the Rubberized Access Cover on the side of the beltstation and plug
the USB end of the Charger/Power Supply into the USB connector. The Lithium-
Polymer batteries will take approximately 2¾ hours to charge from completely
empty to completely full. This time is the same with the beltstation turned on or
off. A new, fully charged battery should power a Tempest beltstation for
approximately nine hours.
Fast charging with the supplied fast charger requires a temperature range of 32°
– 113° F.
Batteries can receive more than 500 charge cycles, and continue to maintain
more than 70% of their power rating. The Tempest battery indicator will maintain
its accuracy as battery life decreases.
Alternatively, remove the Lithium-Polymer rechargeable battery from the beltstation
and insert it into the optional 5-Bay battery charger. The Lithium-Polymer batteries
will take approximately 2½ hours to charge from completely empty to completely full.
See the battery charger manual for additional details.
Power Options
The Tempest beltstation can be powered by
• Supplied Lithium-Polymer battery;
• AA batteries; Note: It is safe to connect a power supply to a beltstation with AA batteries installed.
It will not harm the beltstation, but will not charge the AA batteries.
• Supplied battery charger / power supply.
Beltstation Power On/Off
To turn the beltstation On or Off:
• The Power ON/OFF button is used to turn the beltstation on or off.
• Press and hold the Power ON/OFF button for 2 seconds to turn the beltstation on.
• Press and hold for 4 seconds to turn the beltstation off.